Handheld Capaciteit Meter Lcr Digitale Brug Meter Multifunctionele Inductie Resistance Meter ET430 Et 431 ET432 ET433

USD 122.56USD 175.09

Handheld Capaciteit Meter Lcr Digitale Brug Meter Multifunctionele Inductie Resistance Meter ET430 Et 431 ET432 ET433

Description

Handheld Capacitance meter LCR Digital Bridge Meter Multifunction Inductance Resistance Meter ET430 ET 431 ET432 ET433

ET43 Series Handheld Bridge Introduction:

ET43 series handheld bridge features 2.8” TFT display screen, easy key operation and USB communication. Its high capacity lithium battery ensures long run. It can measure comprehensive parameters, and supports for screening and deviation measurement, with continuously adjustable output frequency. The basic accuracy reaches 0.2%/0.3% Product features: ◆Measurable frequency up to 100k Hz, continuously adjustable at a step of 1 Hz. ◆Measurement of DC resistance and electrolytic capacitor supported ◆Internal bias voltage output (0mV-500 mV) ◆Automatic identification of measured component ◆Support for screening and deviation measurement ◆2.8” TFT display screen, a 4 1/2 digit display ◆USB communication interface ◆Power supply by high capacity lithium battery ◆Support for SCPI protocol ◆System configuration available for setting of language, buzzer and display brightness ◆Basic measuring accuracy 0.2%, adjustable measuring speed ◆Manual and automatic range ◆Open circuit and short circuit calibration ◆Multiple testing ports ET430 Main technical indexes: Testing frequency: 100Hz, 120Hz, 1KHz, 10KHz, 40kHz, 100KHz Basic accuracy: 0.3% Display screen: 2.8” TFT LCD screen Number of display digits: Principal parameter: 5 digit; Secondary parameter: 5 digit Measured parameter: Principal parameter: L/C/R/Z; Secondary parameter: X/D/Q/θ/ESR Electrolytic capacitor mode: yes DCR mode: no Measurement range: L:0.000µH~2000H,C:0.000pF~20.000mF,R:0.0001Ω~20.000MΩ Measuring display speed: 1 time/s (slow), 2 times/s (medium), 4 time/s (fast) Internal bias: no Testing level: 0.3Vrms; 0.6Vrms Calibration function: Open circuit calibration, short circuit calibration Screening function: The limit range of screening can be set to 1%-50%, and the fixed points are 1%, 5%, 10% and 20% Deviation measurement: Used for comparing and displaying deviation percentage of component and the set nominal value Others: Adjustment of backlight brightness, Chinese and English are optional,USB device and automatic power-off time Standard configuration: Mini-USB cable; Power adapter; Short circuit bar; Red and black rubber plug; High capacity lithium battery ET431 Main technical indexes: Testing frequency: 100Hz, 120Hz, 1KHz, 10KHz Basic accuracy: 0.2% Display screen: 2.8” TFT LCD screen Number of display digits: Principal parameter: 5 digit; Secondary parameter: 5 digit Measured parameter: Principal parameter: L/C/R/Z; Secondary parameter: X/D/Q/θ/ESR Electrolytic capacitor mode: yes DCR mode: yes Measurement range: L:0.000µH~2000H,C:0.000pF~20.000mF,R:0.0001Ω~20.000MΩ Measuring display speed: 1 time/s (slow), 2 times/s (medium), 4 time/s (fast) Internal bias: 0-500mV adjustable, at a step of 1mV Testing level: 0.1Vrms, 0.3Vrms, 0.6Vrms,1Vrms Calibration function: Open circuit calibration, short circuit calibration Screening function: The limit range of screening can be set to 1%-50%, and the fixed points are 1%, 5%, 10% and 20% Deviation measurement: Used for comparing and displaying deviation percentage of component and the set nominal value Others: Adjustment of backlight brightness, Chinese and English are optional,USB device and automatic power-off time Standard configuration: Mini-USB cable; Power adapter; Short circuit bar; Red and black rubber plug; High capacity lithium battery ET432 Main technical indexes: Testing frequency: 100Hz, 120Hz, 1KHz, 10KHz, 40kHz, 100KHz Basic accuracy: 0.2% Display screen: 2.8” TFT LCD screen Number of display digits: Principal parameter: 5 digit; Secondary parameter: 5 digit Measured parameter: Principal parameter: L/C/R/Z; Secondary parameter: X/D/Q/θ/ESR Electrolytic capacitor mode: yes DCR mode: yes Measurement range: L:0.000µH~2000H,C:0.000pF~20.000mF,R:0.0001Ω~20.000MΩ Measuring display speed: 1 time/s (slow), 2 times/s (medium), 4 time/s (fast) Internal bias: 0-500mV adjustable, at a step of 1mV Testing level: 0.1Vrms, 0.3Vrms, 0.6Vrms,1Vrms Calibration function: Open circuit calibration, short circuit calibration Screening function: The limit range of screening can be set to 1%-50%, and the fixed points are 1%, 5%, 10% and 20% Deviation measurement: Used for comparing and displaying deviation percentage of component and the set nominal value Others: Adjustment of backlight brightness, Chinese and English are optional,USB device and automatic power-off time Standard configuration: Mini-USB cable; Power adapter; Short circuit bar; Red and black rubber plug; High capacity lithium battery ET433 Main technical indexes: Testing frequency: 100Hz-100KHz Continuously adjustable, a step of 1 Hz Basic accuracy: 0.2% Display screen: 2.8” TFT LCD screen Number of display digits: Principal parameter: 5 digit; Secondary parameter: 5 digit Measured parameter: Principal parameter: L/C/R/Z; Secondary parameter: X/D/Q/θ/ESR Electrolytic capacitor mode: yes DCR mode: yes Measurement range: L:0.000µH~2000H,C:0.000pF~20.000mF,R:0.0001Ω~20.000MΩ Measuring display speed: 1 time/s (slow), 2 times/s (medium), 4 time/s (fast) Internal bias: 0-500mV adjustable, at a step of 1mV Testing level: 10mV-1.1V 1mV adjustable Calibration function: Open circuit calibration, short circuit calibration Screening function: The limit range of screening can be set to 1%-50%, and the fixed points are 1%, 5%, 10% and 20% Deviation measurement: Used for comparing and displaying deviation percentage of component and the set nominal value Others: Adjustment of backlight brightness, Chinese and English are optional,USB device and automatic power-off time

Standard configuration: Mini-USB cable; Power adapter; Short circuit bar; Red and black rubber plug; High capacity lithium battery

Specification

Brand Name : lansl

Capacitance Inductance Resistance Meter : High Precision

Certification : CE

Origin : Mainland China

Model Number : ET430 ET431 ET432 ET433

+