Schakelaar output module 8 relais uitgang isolatie type MODBUS RTU RS485 communicatie

USD 34.33

Schakelaar output module 8 relais uitgang isolatie type MODBUS RTU RS485 communicatie

Description

MB8RO 8 way relay output module, relay can be controlled through the MODBUS bus, the relay can be set on the electric load prefabricated state, or set a power load last relay power down state; control interface for the isolation of RS485, using Modbus-RTU communication, direct fit PLC, DCS and domestic various configuration software.

 

 

The first chapter product introduction

A. Summary

MB8RO 8Road relay output module, the relay can be controlled through the MODBUS bus, the control interface for the isolation of RS485, the use of Modbus-RTU communication, directly with the PLC, DCS, and various domestic configuration software, etc..

The relay output, the power supply and the RS485 communication electrical signals are isolated from each other, which can effectively restrain all kinds of mode and common mode interference, and ensure the reliability of the module.

Two. Characteristic

One Using Modbus-RTU protocol.

2. Relay output, power supply, RS485 communication electrical signals isolated from each other.

Three RS485The communication signal output interface is protected by the overvoltage and overcurrent.

4. Power polarity protection.

Three. Technical index

project

parameter

signal output

1Output channel: 8 normally open relay output

2Load capacity: resistive load 250V/10A inductive load 250V/3A

FiveRelay coil and contact isolation voltage: 1500V

Communication output

1Communication protocol: MODBUS-RTU

2Interface type: isolated RS485 communication, the output of the interface using the overvoltage and overcurrent protection

3Baud rate: 1200BPS, 2400bps., 4800bps, 9600bps, 19200bps

38400bps57600bps, 115200bps.

4Check bit: no parity check, parity check

5. setting: module address, baud rate, parity bit is set up by the software

6Communication distance: 9600bps 1200 meters

SevenIsolated voltage: 1500V

Module size

Separate module size: 115mm*90mm*40mm

Installation method

Standard DIN guide rail installation

work environment

Temperature: -10 ~ +55 temperature humidity: 35~85% (not dew)

Working power supply

1Power supply voltage: 10V~30V wide range of power supply, with the power supply polarity protection

2Power consumption: less than 3W

Four. Product appearance

 

Five. External wiring diagram

1. Relay output method

2. Communication and power supply connection

 

Six. Module indicator lamp and switch function specification

1. POW/SET;Module working status indication

A.Green light: the module works in the running state. B. red light: the module is configured to write parameters, need to re power up.

2. TXD/RXD:Communication status indication

A.The green light flashes: the communication receives the data B. red light flashes: the module is sending data

C.The green light is always on: DATA+ and DATA- on the communication line RS485 line is connected to the reverse or the connection is broken.

Three Module right reset switch

1) When the communication parameters (module address, baud rate, parity bit) do not know or communication parameter misspecification, and can not establish contact module communication, the solution is to reset the communication parameters; we use the clip to hold the reset switch is not open, 5 seconds after the [POW/SET] module of the red indicator lights, release the reset switch, the communication the parameters have been reset, as long as the power supply module after the restart time, the communication parameters of the module has been reset.

2) Communication parameters after reset: Address: 1, baud rate: 9600bps, parity: No.

Seven. Principle block diagram

Eight. MODBUSRegister description

1. Module supports MODBUS function code

Code

Meaning

operation

0x01H

Read more than one coil register

Read the values of one or more coil registers

0x03H

Read more than one hold register

Read one or more of the value of the register.

0x05H

Write a coil register

Write the value of a coil register

0x 06H

Write a single hold register

Write a data to hold register

0x0FH

Write one or more coil registers

Write one or more of the value of the coil register

0x 10H

Write more than one hold register

Write one or more data to hold registers

2. Register definition description

1) Coil register0x01H,0x05H,0x0FH)

address

parameter

read/write

minimum value

Maximum value

Explain

00001

RO0

Read and write

0

1

Relay output0

00002

RO1

Read and write

0

1

Relay output1

00003

RO2

Read and write

0

1

Relay output2

00004

RO3

Read and write

0

1

Relay output3

00005

RO4

Read and write

0

1

Relay output4

00006

RO5

Read and write

0

1

Relay output5

00007

RO6

Read and write

0

1

Relay output6

00008

RO7

Read and write

0

1

Relay output7

2) Hold register0x03H,0x06H,0x10H)

address

parameter

read/write

minimum value

Maximum value

Explain

40065

Equipment type

read-only

0

256

2 (MB8ROModule)

40066

Equipment status

read-only

0

0x0101

Bit4Reset button state

Bit0Module reset request flag

40067

Module voltage

read-only

0

300

0.0-29.9V

40069

product version

read-only

0

65535

Hardware version(high8position+)Software version(low8position)

40070

production information

read-only

0

65535

year(high8position+)Batch number(low8position)

40071

Module address

read/write

1

Specification

Model Number : MB8RO

Communication type : RS485 MODBUS-RTU

Characteristic : Signal acquisition, RS485 communication, the main power of mutual isol

Technology : Industrial patch design

Contact capacity : 10A 250V , 3A inductive load

Condition : New

Type : Logic ICs

type of output : 8 normally open relay output